Table of Contents Testing Cables and Breakout Boxes Subject Page Connectors.5 Connector Contact Removal Kit.5 Socket and Spring Contacts.5 Instrument Cluster Illumination Bulb Holder Removal Socket.6 Relay Holder Disengaging Tool .6 Circular Connector Lock Disengager .7 BMW Plug System Abbreviations.7 Plug System D1.5/D2.5 .8 Circular Plug 7-8 Pin System D2.5.8 Circular Plug 20 Pin System D2.5.9 Circular Plug 4-7-10-12-25 Pin System D1.5/D2.5 .9 In-line Plug 15 Pin System D2.5.10 In-line Plug 8-, 12 Pin System D2.5.10 In-line Plug 20 Pin System D2.5.11 In-line Plug 30 Pin System D2.5.11 Plug System JPT/MDK/DFK.12 In-line plug 2 Pin System JPT ELA .12 In-line plug 2 Pin System MDK3 plus 2.8 .12 In-line plug 4 Pin System DFK ELA.13 Installation Instructions .13 Plug System Elo/Elo-Power.14 In-line Plug 3-,6 Pin System Elo-Power2.8 .14 In-line plug 4-,10 Pin System Elo.14 In-line Plug 6-,50 Pin System Elo.15 Plug System MQS/MPQ .16 In-line Plug 6-,8 Pin System MQS .16 In-line Plug 2 Pin System MPQ 2.8 .16 Control Unit Plug 25-, 35-, 55-,83-,88 Pin .17 In-line Plug 24 Pin Hybrid System MQS/MPQ.17 Socket Housing .17 Pin Housing.18 Socket Housing 42-,43 Pin Hybrid Systems MQS/MPQ.19 Installation Instructions .19 Socket Housing 2x27-, 2x27 Pin Hybrid System MQS/MPQ, Elo/Elo Power .19 In-line Plug 30 Pin Hybrid System MQS/MPQ.20 Socket Housing .20 Initial Print Date: 05/01 Revision Date: 10/10 Subject Page Pin Housing.21 Socket Housing 5-, 8 Pin System MQS/MPQ.21 Socket housing 5pin (Hybrid System MQS/MPQ) .21 Socket Housing 8 Pin (MQS).22 Socket Housing (Radio Plug) Hybrid System MQS/MPS.22 Removing MPQ Contacts from Radio Plug.22 Removing MQS Contacts from Carrier .23 Removing MPQ Contacts from Contact Carrier.23 Miscellaneous Connectors .24 Fuse Strip.24 ECM Main Relay Connector.24 Solderless Terminals And Connectors .25 Electrical Repair.26 Electrical Repair Kit IV.26 Cable Stripper.26 Crimping Tool .26 Cable Stripping .27 Crimping Tool.28 Prepackaged Wiring Repair Sets .30 Soldering Connections.31 Soldering Preparation and Procedure.31 Break Out Boxes and V Cables,Tester and Adapter Sets.32 Breakout Boxes and “V” Cables.32 55 pin Breakout Box P/N 81 12 9 425 091 .33 83 Pin Breakout Box (Red Face) P/N 90 88 6 614 420 .33 88 Pin Breakout Box (Green Face) P/N 88 88 6 614 410.33 134 Pin SKE Control Module Breakout Box Set P/N 90 88 6 121 300 .34 26 Pin Breakout Box P/N 88 88 6 611 459 .34 60 Pin Breakout Box P/N 90 88 6 614 390 .34 “V” Cables.35 Tester and Adapter Set for Relays .36 Subject Page Testing Cables and Breakout Boxes Model: All Production: All After completion of this module you will be able to: • Recognize and distinguish the various Electrical Repair Kits. • Use the Connector Removal Kit. • Recognize the plug configurations and disassemble them properly. • Repair wiring harnesses and connectors. • Choose the proper Breakout Box and “V” cable for testing. • Use the relay testing tool. 4 Testing Cables and Breakout Boxes Connectors Connector Contact Removal Kit The connector contact removal kit provides tools for the disassembly of connectors. Proper use of these tools enable the techni¬ cian to access wiring connectors for repairs equal to factory quality. Always refer to the latest Service Information Bulletins (Group 04) for up to date information regarding new tools. The Connector Contact Removal Kit is used for: • Releasing round plug housings. Current P/N 88 88 6 611 150 • Pressing out contacts. • Pulling out indicator lamps. • Releasing relay carriers. Socket and Spring Contacts Socket and Spring contacts compress the springs while the connector is pushed from the housing. 5 Testing Cables and Breakout Boxes Flat spring contacts depress the spring allowing the connector to be pushed or gently pulled from the connector housing. Instrument Cluster Illumination Bulb Holder Removal Socket The backlighting illumination bulbs are removed from the cluster by placing square head of the socket on the bulb holder and turning 90° counter clockwise. The bulb removal socket is used on all instru¬ ment clusters. Relay Holder Disengaging Tool This tool allows the relay holder (2) to disen¬ gage the relay connector (1). 6 Testing Cables and Breakout Boxes Circular Connector Lock Disengager These tools unlock the circular connector hous¬ ings allowing the individual connectors to be removed. The various sizes are reflected in the part num¬ bers: 4 pin = 61 1 141 7 pin = 61 1 142 10 pin = 61 1 145 12 pin = 61 1 143 25 Pin = 61 1 144 BMW Plug System Abbreviations D 1.5/2.5 Round contacts of 1.5mm or 2.5mm diameter MDK 3 Plus Miniature double flat spring contact JPT ELA Junior Power Timer flat spring contacts with strand sealing DFK ELA Double flat spring contacts with strand sealing Elo Electronic contacts with and without strand sealing Manufacturer: Siemens Elo Power Electronic contacts for heavy loads with and without strand sealing Manufacturer: Siemens MQS Micro Quadlock System electronic contacts with and without strand sealing Manufacturer: AMP MPQ Micro Power Quadlock electronic contacts for heavy loads with and without strand sealing Manufacturer: AMP 7 Testing Cables and Breakout Boxes Plug System D1.5/D2.5 Circular Plug 7-8 Pin System D2.5 • Pull off the rubber boot (1). • Push the retaining lugs (2) of the inner connector section 3 inward carefully to disen¬ gage the lock notch. • Push the inner connector section (3) in the direction of the arrow in the illustration until the retaining lugs (2) are in the recessed notch (4) and use the appropriate sized spring contact tool and remove the connector from the housing. Circular plug 13 Pin System D2.5 • Carefully pull off the rubber grommet (1). • Pull the lock retainers (2) outward (direction of arrows) to allow the lock notch to dis¬ engage. • Pull the inner section (3) upward as shown in the illustration until the lock notches (4) are in the released position of the lock retainers (5) and use the appropriate size spring contact and remove the connector from the housing. 8 Testing Cables and Breakout Boxes Circular Plug 20 Pin System D2.5 • With the boot pulled back, press the lock tabs (1) of the inner connector section (2) inward. • Simultaneously, rotate the inner connection section (2) counter clockwise to allow the lock tabs (1) to engage in the unlocked position and use the appropriate sized spring contact and remove connector from the housing. Circular Plug 4-7-10-12-25 Pin System D1.5/D2.5 • Insert the appropriate unlocking tool (determined by the number of pins) into the connector. • The connector is unlocked when the lock tab (3) is in the unlocked position (1). The connector is locked when the lock tab (3) is in the locked position (2). • Use the appropriate sized spring contact and remove connector from the housing. 9 Testing Cables and Breakout Boxes In-line Plug 15 Pin System D2.5 • Pull the outer connector section (1) slightly outward in the area of lock tabs (2). • Simultaneously, slide the inner connector section (3) in the direction of the arrow to the unlocked position. • Use the appropriate sized spring contact and remove connector from housing. • Slide the upper section (1) and the lower section (2) of the connector in opposite directions to unlock the connector. • Using special tool 61 1 132 press the spring latch down and pull the connector (3) from the housing. 10 Testing Cables and Breakout Boxes In-line Plug 20 Pin System D2.5 • Pull locking slide (1) completely out of connector (2). • Using special tool 61 1 132 press the spring latch down and pull the connector from the housing. In-line Plug 30 Pin System D2.5 • Pull the outer section (1) slightly outward in the area of lock tabs (2). • Simultaneously, slide the inner connector section (3) in the direction of the arrow to the unlocked position. • Use the appropriate sized spring contact and remove connector from housing. 11 Testing Cables and Breakout Boxes Plug System JPT/MDK/DFK In-line plug 2 Pin System JPT ELA • Press lock (1) in direction of arrow and slide plug forward. • Press lock (1) downward and slide out to one side. • Unlock contact with special tool 61 1 136 and pull out cable (2) and contact towards rear. In-line plug 2 Pin System MDK3 plus 2.8 • Unlock lock (1) on outside at arrester hook and slide out lock (1) side. • Unlock contact with special tool 61 1 136 and pull out cable (2) and contact towards rear. 12 Testing Cables and Breakout Boxes In-line plug 4 Pin System DFK ELA • Press arrester hook in direction of arrow and remove lock (1). • Unlock contact with special tool 61 1 136 and pull cable and contact out towards rear. Installation Instructions • If necessary, slide lock must also be unlocked with screw driver. 13 Testing Cables and Breakout Boxes Plug System Elo/Elo-Power In-line Plug 3-,6 Pin System Elo-Power2.8 • Press unlocking hook (1) in direction of arrow and disengage. Then unlock locking hook (2) and remove lock. • Press down arrestor hook (3) with screwdriver and pull out cable with contact towards rear. In-line plug 4-,10 Pin System Elo • Slide connector lock (1) off of main connector body. • Push the lock tab of the connector being removed down (3) with pin or small screw¬ driver in the primary lock slot(4) and pull the wire out (5) to the secondary lock position (6). • Push the lock tab down again in the secondary lock position and remove wire com¬ pletely. 14 Testing Cables and Breakout Boxes In-line Plug 6-,50 Pin System Elo • Unlock lock (Fig. 14/1). • Unfasten cable clip (Fig. 14/2). • Slide connector lock (1) off of main connector body (2) (Fig. 14/3). • Push the connector plate (3) out of connector shell using a small screwdriver through hole on end of connector body (Fig. 14/4). • Push the lock tab of the connector being removed down (6) with pin or small screw driver in the primary lock slot (7) and pull the wire out to the secondary lock position (8) (Fig. 14/5). • Push the lock tab down again in the secondary lock position and remove wire com¬ pletely (Fig. 14/6). Fig. 14/1 Fig. 14/2 Fig. 14/3 Fig. 14/4 Fig. 14/5 Fig. 14/6 15 Testing Cables and Breakout Boxes Plug System MQS/MPQ In-line Plug 6-,8 Pin System MQS • Press lock (1) in direction of arrow and slide plug forward. • Press locking hook (2) downward and slide lock (1) out. • Press down arrester hook (3) with screwdriver and pull out cable with contact towards rear. line Plug 2 Pin System MPQ 2.8 • Press catch on outside in direction of arrow and remove towards top. • Press down arrestor hook (1) with screwdriver and pull out cable and contact (2) towards rear. 16 Testing Cables and Breakout Boxes Control Unit Plug 25-, 35-, 55-,83-,88 Pin • Remove phillips head screws (1) from connector. Gently pivot the connector plate (2) with seal (3) out of the connector shell. • Remove seal (3) and pull connector plate lock (4) out of locked position. • Using the appropriate sized spring contact and remove connector (5) from housing. In-line Plug 24 Pin Hybrid System MQS/MPQ Manufactured by AMP: The following contact types without strand sealing can be fitted in the plug housings: MQS (Micro Quadlock System) MPQ, width 2.8 mm (Micro Power Quadlock) MPQ, width 5.2 mm (Micro Power Quadlock) Socket Housing • Press locks (1) on cap (2) upwards on both sides. • Detach cap from contact carrier (3). Note: Detaching the cap releases the secondary lock of the socket contacts. 17 Testing Cables and Breakout Boxes • Hold down retaining hook (1) of socket contact carrier with a small screwdriver. • Pull wire with socket contact in direction of arrow as far as secondary lock (2). (Fig. 17/1) • Hold down retaining hook in secondary lock (1) again and pull cable with socket contact (2) completely out of contact carri¬ er (3). (Fig. 17/2) Pin Housing • Press locks (1) on cap (2) upwards on both sides. • Detach cap from housing carrier (3) (Fig. 17/3). Note: Detaching the cap releases the secondary locks of the pin contacts in the contact carriers. • Pull contact carrier (1) out of housing carrier (2) (Fig. 17/4). • The pin contacts are pulled of a contact carrier as described under “Socket Housing”. Fig. 17/1 Fig. 17/3 Fig. 17/4 18 Testing Cables and Breakout Boxes Socket Housing 42-,43 Pin Hybrid Systems MQS/MPQ Manufactured by AMP: The following contact types without strand sealing can be fitted in the socket housings: MQS (Micro Quadlock System) MPQ, width 2.8 mm (Micro Power Quadlock) MPQ, width 5.2mm (Micro Power Quadlock) • Open secondary locks (1) on socket housing. • Press back retaining hook of MQS contacts (2) with special tool 61 1 134 and pull out cable with contact. • Press back retaining hook of MPQ contacts (3) with screwdriver or similar tool and pull out cable with contact. Installation Instructions Bend open retaining hook of contacts gently before inserting into plug housing, To install contacts, observe cavity numbers on reverse side of socket housing. tj=j)cn* BaBBaBBOBiiC? BSEDB30BD”" DQOSQDQGSu (2)_ HE) JL X X 1 -J Socket Housing 2x27-, 2x27 Pin Hybrid System MQS/MPQ, Elo/Elo Power Manufactured by Amp: The following contact types without strand sealing can be fitted in the socket housings: MQS (Micro Quadlock System) MQS, width 2.8 mm (Micro Power Quadlock) MPQ, width 5.2 mm (Micro Power Quadlock) 19 Testing Cables and Breakout Boxes Manufactured by Siemens: The following contact types without strand sealing can be fitted in th socket housings: Elo (electronic contact) Elo-Power 2.8 mm wide (electronic contact for heavy loads) Elo-Power 5.2 mm wide (electronic contact for heavy loads) • Raise lock (1) on housing (2). • Push contact carrier (3) from rear out of housing. Note: The second carrier is pushed out in the same way. Pushing out the contact carrier releases the sec¬ ondary locks of the secondary con¬ tacts. Procedure for removing contacts are same as for other Elo/Elo-Power Systems, refer to those instructions. In-line Plug 30 Pin Hybrid System MQS/MPQ Manufactured by AMP: The following contact types without strand sealing can be fitted in the plug housings: MQS (Micro Quadlock System) MPQ, width 2.8 mm (Micro Power Quadlock) MPQ, width 5.2 mm (Micro Power Quadlock) Socket Housing • Raise lock (1) on housing (2). • Push contact carrier (3) from rear out of housing (2). Note: Pushing out the contact carrier releases the secondary locks of the socket contacts. Procedure for removing contacts are same as for other Elo/Elo-Power Systems, refer to those instructions. 20 Testing Cables and Breakout Boxes Pin Housing • Contact 1...13 and 19...27. • Raise locking slide(l) on both sides (2) of housing and detach. Note: Detaching the locking slide releases the secondary locks of the pin contacts. • Contacts 14...18 and 28...30. • Pull slide (1) outward completely. • Raise lock (2) on housing. • Pull contact carrier out of housing. Note: Pulling out the contact carrier releases the secondary locks of the pin contacts. Socket Housing 5-, 8 Pin System MQS/MPQ Manufactured by AMP: The following contact types without strand sealing can be fit¬ ted in the socket housings: MQS (Micro Quadlock System) MPQ, width 2.8 mm (Micro Power Quadlock) MPQ, width 5.2mm (Micro Power Quadlock) Socket housing 5pin (Hybrid System MQS/MPQ) • Raise fastener (1) (slide) by way of retaining lug (2) and detach from contact carrier (3). 21 Testing Cables and Breakout Boxes Socket Housing 8 Pin (MQS) • Raise fastener (1) (slide) by way of retaining lug (2) and detach from contact carrier (3). Procedure for removing contacts are same as for other Elo/Elo-Power Systems, refer to those instructions. Socket Housing (Radio Plug) Hybrid System MQS/MPS Manufactured by AMP: The following contact types without strand sealing can be fitted in the plug housings: MQS (Micro Quadlock System) MPQ, width 2.8 mm (Micro Power Quadlock) MPQ, width 5.2 mm (Micro Power Quadlock) Removing MPQ Contacts from Radio Plug • Press lock (1) in direction of arrow, detach secondary lock (2) from radio plug. • Feed special tool 61 1 135 past side of contact. • Press special tool 61 1 135 in direction of arrow. • Pull wire (1) with socket contact out of radio plug(2). 22 Testing Cables and Breakout Boxes Removing MQS Contacts from Carrier • Press lock (1) in direction of arrow and pull housing (2) out of radio plug (Fig. 22/1). • Press lock (1) in direction of arrow. Pull contact carrier (2) out of housing (Fig. 22/2). Note: When the contact carrier is pulled out, the secondary locks of the socket contacts are raised. Procedure for removing contacts are same as for other Elo/Elo-Power Systems, refer to those instructions. Fig. 22/1 Fig. 22/2 Removing MPQ Contacts from Contact Carrier • Remove contact carrier (1) with MQS contacts from radio plug. Raise lock (2) on radio plug. Pull contact carrier (3) out of radio plug (Fig. 22/3). • Press lock (1) in direction of arrow. Pull secondary lock (2) in direction of arrow completely out of contact carrier (3) (Fig. 22/4). • Press special tool 61 1 135 on inside of contact into contact carrier(2). Pull wire with socket contact (1) out of contact carrier (2) (Fig. 22/5). Fig. 22/3 Fig. 22/4 Fig. 22/5 Miscellaneous Connectors Fuse Strip • Pull appropriate fuse from fuse strip (1). Note: Mark fuse rating and position for reinstallment. • Pull locking slide (2) out of fuse strip until stop is felt. • Using special tool 61 1 136 or 61 1 1 ECM Main Relay Connector • Unlock wire flap (1) of connector being removed. • Using special tool 61 1 136 or 61 1 137 press the spring latch down (2) and pull the connector from the housing.37 press the spring latch down (3) and pull the con¬ nector from the housing. Solderless Terminals And Connectors Mechanical strength of solderless terminal design and electrical conductivity must be maintained at all times. To ensure these characteristics are maintained in the vehicles electrical system several BMW repair kits are available. The repair kits listed contain all the approved connectors, pins, and tools required for proper repair of BMW's electrical, electronics compo¬ nents. • Electrical Repair Kit IV P/N 90 88 6 619 020 The Electrical Repair Kit IV (Ref. SI. 04 18 92) is used in conjunction with the instruction manuals and detailed repair manual proce¬ dures from Group 61, Sub-group 13 found in TIS. These procedures include: • Disassembling, replacing a plug connection • Cutting cable to length. • Crimping stop parts (Contacts). • Butt connectors for repairing a plug connection. Operating instructions for special tools and the handling of individual parts in the repair kit are available under PN 61 9 029. Three previous kits issued by BMW are: • Electrical Repair Kit I (Black Case) P/N 81 24 9 408 080 • Electrical Repair Kit II (Blue Case) P/N 81 24 9 408 300 • Electrical Repair Kit III (Red Case) P/N 82 11 9 408 400 Electrical repair kits I, II and III are primarily needed for repairing wiring harness and con¬ nectors of older vehicles (E30 and earlier). Refer to repair kit instructions, SI bulletins and repair manual microfiche. Operating instructions for special tools in these kits are avail¬ able under PN 61 8 084. on the various types of connectors. 25 Testing Cables and Breakout Boxes Electrical Repair Electrical Repair Kit IV The Electrical Repair Kits (1,11,111 and IV) have gone through various upgrades. Electrical Repair Kit IV (PN 90 88 619 020) has been developed to handle repairs of the specialized state of the art wiring and har¬ nesses of the newest BMW products. Caution: The special tools contained in the Electrical Repair Kits 1,11,111 are not state of the art and are not suitable for specialized wiring harness repairs. Use exclusively Electrical Repair Kit IV for those repairs. Electrical Repair Kit IV (61 9 020) Contains the following: 61 9 041 Crimping Tool 61 9 042 Matrix 61 9 043 Cable Stripper 61 9 044 Matrix Assorted Individual Parts Cable Stripper Special Tool 61 9 043 Cable stripper with wire cutter for cutting and stripping insula¬ tion from cables. Crimping Tool Special Tool 61 9 041 Crimping Tool with special tool 61 9 044 (matrix) for crimping cable guide and strain relief device on anten¬ na elbow plug. Supplementary kits for Electrical Repair Kit IV are released periodically. Check the latest Service Bulletin to insure information on latest connectors are avail¬ able. 26 Testing Cables and Breakout Boxes Cable Stripping Proper wire stripping and connector replace¬ ment is essential to ensure the integrity of the electrical connection. Always follow specific instructions in the Electrical Repair Kit IV instruction manual as well as Group 61-13 repair manual found in the TIS. The length of wire to be stripped is deter¬ mined by the wire gauge. Wire cross-section size Stripped length: mm 2 mm 0.35 ... 0.50 4.0 0.75 ... 1.00 4.5 1.00... 2.50 5.0 Proper use of the wire stripping tool will pro¬ vide consistently positive results. Insert the wire (1) into the stripper. Stop the wire when the required strip length is past the cutter (2). Squeeze the handle of the tool. When the top jaw of the tool touches the wire (3) the mechanism shifts the clamping action to a pulling action which strips the wire of the insulation (4). 27 Testing Cables and Breakout Boxes Crimping Tool Use the wire crimper from the BMW Electrical Repair Kit. This crimper is designed for the specific connectors found in BMW automobiles. Proper use of the tools will provide consistent good quality connec¬ tor crimps. The crimper is designed to apply just the right amount of pressure based on the wire gauge and connector size. The tool has removable crimper jaws (3). This feature allows for an unlimited number of connector types for future compatibility. The repair manual refers to the different sized crimping slots as “Nests”. The gauge of the wire being crimped determines which “Nest” is used. Nest Wire cross-section size 1 0.35... 0.50mm 2 2 0.75... 1.00mm 2 3 1.50mm 2 4 2.50mm 2 Example: A .75 -1 .Omm gauge wire requires nest 2 for proper crimping. Throughout the Electrical Repair Kit instruc¬ tion manual are illustrations of various con¬ nectors being crimped. The highlighted box of the 16 box grid in these illustrations refers to the storage compartment in the electrical kit drawers in which that specific connector can be found. Insert the “crimping end” of the connector into the appropriate “nest”. Illustration pro¬ vides example of comb replacement connec¬ tor (4) and inline splice connector (5). 28 Testing Cables and Breakout Boxes Squeeze the tool handle slightly to set the tool in the first ratchet latch position. This will hold the connector in the tool without closing the crimp (6). Insert the stripped wire into the receiving end of the crimper tool making sure the wire is inserted far enough to ensure that only the wire insulation will be inside the insulation support barrel (7). Properly crimped connectors exhibit the fol¬ lowing characteristics: • The insulation support barrel will be crimped consistently and snug against the insulation. The insulation will not be crushed (8). • A bellmouth crimp will be visible at the wire end of the of the wire barrel (9). • Wire strands will be visible at the contact end of the wire barrel (10). • Insulation end will be visible in this area (11) (Fig. 27/1). The following are examples of unacceptable crimps: (Fig. 27/2) • Excessive or no wire strands at the contact end of the wire barrel (10). • Excessive or no insulation end in the acceptable area (11). Testing Cables and Breakout Boxes Prepackaged Wiring Repair Sets Included with the Electrical Repair Kit IV are a variety of wiring repair sets. These sets con¬ tain various pre-crimped wiring connectors on assorted gauge wire lengths for simple splice connection repair into a wiring harness. The repair kits also contain: 1. Various gauge lengths of wire with pre-crimped connectors. 2. In-line splice connectors. 3. Heat shrink tubing. When used correctly the in-line splice con¬ nectors provide a BMW factory approved wire crimp. Use the correct size nest in the crimper tool and connect one side of the in¬ line crimp with the wire. Slide a piece of heat shrink tubing on the wire and crimp the other side of the in-line con¬ nector. Use a heat gun to shrink the tube around the splice connector to provide a moisture resis¬ tant seal. Part numbers for the wire sets or any compo¬ nent of all four electrical repair kits can be re¬ ordered from: • The P/N reference card inside each repair kit. • Special tools microfiche. • The Electrical Repair Kit 1 -4 compo¬ nent catalog (SD 92-036). As new connectors are developed for new vehicles, the repair kits will be announced by Service Information bulletins and sent to dealerships via automatic tools shipment. 30 Testing Cables and Breakout Boxes Soldering Connections In the event that a wiring connection must be soldered in a vehicle’s electrical system, there are certain procedures which must be fol¬ lowed. Improper soldering will result in poor electrical connections or damage to electrical components. SAFETY: Adhere to the following basic guidelines when preparing to solder. • Safety glasses must be worn. • Disconnect vehicle battery. • Cover vehicle trim surfaces. • Exercise your common sense. • Provide adequate ventilation, it’s the best safety precaution! Soldering Preparation and Procedure • The wire insulation must be stripped to expose an adequate amount of bare wire (not too little-not to much.) • The wires and or connectors must be clean and free of grease, dirt, wax, etc. • A thin coating of rosin core flux must be applied to the soldering connection. PREHEAT DON'T BURN INSULATION Have enough 60/40 (tin/lead) general electrical solder on hand prior to starting. If heat transfer to a heat sensitive component is possible use “heat sinks”. Use a soldering gun tip that is the right size for the job. Do not use an overly large tip which could melt wire insulation and block your view of what is being soldered. The soldering tip must be “tinned”. This means to keep a thin layer of solder on the tip at all times during soldering. This will transfer the heat quickly and allow the sol¬ der to flow easily into the joint being soldered. Preheat the wires or connector. Introduce the solder into the joint not the soldering tip. When the solder starts to flow allow it to infiltrate the joint only for a moment. Almost simultaneously, pull the tip off of the joint to prevent overheating. A properly soldered joint will be smooth, shinny, and even surfaced. 31 Testing Cables and Breakout Boxes Break Out Boxes and V Cables, Tester and Adapter Sets Breakout Boxes and “V” Cables Breakout Boxes are used to: • Provide a convenient “tap” into an electrical circuit. • Minimize the possibility of damage to control unit connections and wire harnesses during diagnosis of electrical/electronic systems. • Ensure solid meter connections for proper diagnosis, this in turn will help the tech¬ nician to be more organized and efficient. • Provide easier access to circuits fortesting with equipment such as, multimeter, DISplus tester or other diagnostic tools. CAUTION: Breakout box cable connections are universal in order to fit the varying coded connectors found in the vehicles. Always confirm that you are connecting the correct control module into the sys¬ tem harness that is on the other side of the breakout box. System damage will occur if it is not the correct system. Example: DME and EGS/AGS control modules both utilize an 88 or 134 pin control module. These control modules reside in the same E-Box on most vehicles. The con¬ trol modules are coded to prevent unintentional cross connecting at the vehicle harness. But, this connector coding is not present on the 88 or 134 pin breakout box(s). Result: A DME control module could be connected to a transmission control system. Damage will result! Several different types of breakout boxes are available depending on the particular sys¬ tem being diagnosed. 32 Testing Cables and Breakout Boxes 55 pin Breakout Box P/N81 12 9 425 091 Used with control modules that have single multi-pin plugs from 25 to 55 pins. • L-jetronic • ABS • Motronic • EGS Adapter cables are required. 83 Pin Breakout Box (Red Face) P/N 90 88 6 614 420 When used with ABS/ASC 5 system, no adapter cables are required. See SIB 04 10 95 about an adapter harness for use with the Teves Mark IV G ABS system of the E36. 88 Pin Breakout Box (Green Face) P/N 88 88 6 614 410 Used with control units that have up to 88 pins; • DME • EGS/AGS • ZAE/MRS • LCM No adapter cables are required when con¬ nected to a DME or EGS/AGS control mod¬ ule. See SB’s 04 26 96 and 0415 96 about adapter harnesses for ZAE/MRS and LCM systems. 33 Testing Cables and Breakout Boxes A PUXSTIC KEY IN THE CONNECTOR OF THE BREAK OUT BOX PREVENTS CONTACTS IN THE WIRING HARNESS CONNECTOR FROM TOUCHING. THIS KEEPS THE ABS AND IF EQUIPP THE ASC INDICATORS FROM BEING "ON" WHEN DIAGNOSING □ □ B |CvP □ □ □ n □ b h b a □ □ o o o o BflBBBBBOHSHBDn BBBBBBBB □ □ U B □ UJJ \ 134 Pin SKE Control Module Breakout Box Set P/N 90 88 6121 300 The 134 pin modular connector DME and AGS control modules use a combination of breakout boxes fortroubleshooting. The part number above provides three breakout boxes and five adapter harnesses. The two outside edge connectors use the familiar 26 pin breakout boxes. The three inside connectors use the boxes from the ordered set. VEHICLE HARNESS 26 Pin Breakout Box P/N 88 88 6 611 459 Used with system or peripheral control mod¬ ule that have up to 26 pins. This breakout box is used in conjunction with adapter cables called “V” Cables. There are many dif¬ ferent types of “V” cables for the various con¬ nectors found on the vehicles. 60 Pin Breakout Box P/N 90 88 6 614 390 Used for connecting all adapter leads with 27 pin to 60 pin plug connections. 34 Testing Cables and Breakout Boxes “V” Cables “V” cables are available in different versions depending on the system being diagnosed. Always refer to the most recent Service infor¬ mation for the required special tools. “V” cables are only used with the 26 pin break¬ out box to access input and output signals of peripheral modules and systems. • The appropriate cable is distinguished by the color of the connector end. • The color will match the particular modules connector color. Unless the color matches, the cable will not fit the connector on the module being tested. • Each colored “V” cable has a series of alignment tabs that will only fit it’s particular module or system. “V” cables with ELO connectors are also being used with the 26 pin breakout box. These cables are unique in that they have a locking arm on the component side of the cable. They are light green in color, and the number of pins will vary depending on the system being tested. “V” harness adapters were introduced with the E38. These also have light green ELO connectors on the component side, but they do not require a breakout box. There is a black plug on one side with same number of pins as the component being tested. The plug has numbers stamped on it’s side that corresponds with the pins on that particular component. You access the signals by plugging the test equipment directly into those pin numbers. As new systems and components are being introduced, new breakout boxes and cables will also be introduced. Always remember to refer to the most recent service information in TIS or Service Information Bulletins for the latest diagnostic tools and procedures. 35 Testing Cables and Breakout Boxes Tester and Adapter Set for Relays The Relay Adapter provides a platform to test a relay while allowing the relay to remain active in a circuit. The adapters included enable different pin con¬ figurations of relays to be tested using a single tester. Remove relay and compare plug in adapter with plug pattern on relay. Choose correct adapter (Fig. 33/1). Fit adapter to Measuring bridge, noting the marker arrows (A). Fit the relay to the measuring bridge (Fig. 33/2). Plug the assemble measuring bridge into the socket of the relay to be checked. Test using a multimeter. See the circuit diagram, testing instructions and repair manual for subsequent procedure (Fig. 33/3). 36 Testing Cables and Breakout Boxes Examples of V cables Part number Description Chassis Use 61 1 260 30 Pin V cable E46 Wiring door harness 61 1 270 24 Pin V Cable E46 Connection on seat plug 61 1 460 Set of 8 cables E32,36,38 Door harness and others 61 1 480 Set of 7 cables E30,32,34 Various electrical systems 61 1 490 Set of 2 cables E34 Engine wiring harness 61 2 050 2 Pin V cable (JPT) E31,32,34 Servotronic 61 2 070 Set of 3 cables E36,38,46, Electrical front seat 61 3 030 V cable E38 DSC 3 control module 61 3 150 54 Pin adapter E46 Light module 61 3 190 Test Leads E38,39 EWS 61 3 210 5 Pin V cable E46 Seat heating 61 3 220 8 Pin V cable E46 Power window and interior light 61 3 240 8 Pin V cable E46 Door locks 61 4 350 V cable E38,39,46 Center console switch 61 4 450 20 Pin V cable E30,31,36 LKM and EM convertible top 61 4 460 Set of 4 26 pin cables E31,34,36 Various electrical systems 61 6 020 Set of 6 cables E38 Various electrical systems 61 6 030 Set of 5 cables E38 Various electrical systems 61 6 040 Set of 5 cables E38 Various electrical systems 61 6 050 6 Pin V cable E39,46 Various electrical systems Important Notes Concerning Airbag Repairs: Only repair those cables which show visible signs of damage. If there is visible damage, make sure that only one cable repair is present after repairing. If no visible damage can be identified, the entire cable must be replaced. When carrying out repairs to the airbag wiring harness use only those parts specified in the EPC as “Airbag Repair Cable”. Airbag Repairs Always refer to the latest SIB for information pertaining to the latest Airbag repair procedures. SIB 61 02 00 Plug Adapter Relay Tester Part Number 61 3 013 61 3 014 61 3 015 61 3 017 61 3 018 61 3 019 61 3 021 61 3 016 Use Crash Sensor Hazard Warning System Hazard Warning System C2 Changeover Relay N/O (Normally Open) Relay Rear Window Heater Windscreen Heater ABS 37 Testing Cables and Breakout Boxes 38 Testing Cables and Breakout Boxes